+86-21-5432 2103

PV Module Aging Test Location: 首页 > Product Solutions > PV Module Aging Test > PID Test System (Single Control Scheme)

PID Test System (Single Control Scheme)

Product description Specifications Download

 Meet the PID test requirement specified in the IEC62804 standard.


The frame end of the module is grounded, which not only simulates the actual situation, but also prevents the potential danger caused by the high pressure of the frame during the test process

For each module, use the 4-wire test method, that is 2 high-voltage cables, and 2 ground cables. The high-voltage cables are connected to the inside of the module through the terminal box. The ground wire is connected to the frame or connected to other effective positions

Multiple currents are displayed at the same time, while alarm parameters are set separately, with single-circuit on/off control

Multi-channel voltage settings are programmed separately and the voltage can be set as required.

Forward and reverse voltage could be set by program;

Conversion of positive power supply and negative power supply, which is simulation of positive ground or negative ground. 

Can set test time, and stop automatically;

The screen shows the test situation, and record the test data;

Test channels can be customized according to customer needs;

Can test and record environmental parameters and temperature parameters.

Project

Parameters

Size

650mm*650mm*1600mm

Weight

30kg

voltage range

-1500V0V/ 0+1500V

Source effect

0.2%

Time drift

0.3%/h

Temperature drift

0.5/

Ripple

0.5%

Alarm setting range

11000 uA /-1000 uA1

testing time

Can be set

Insulation resistance

1000MΩ

temperature range

RT+10+110

Temperature control stability

±0.5

Temperature uniformity

±2.0

Heating rate

Meet the heating rate of 5°C/min.

Humidity control range

7095%RH

Humidity control stability

±2.0%RH

Humidity uniformity

±3.0%RH